Microprocessor-Based Relay Testing, Feeder Protection (MBRFP)

Microprocessor-Based Relay Testing, Feeder Protection (MBRFP)Microprocessor-Based Relay Testing, Feeder Protection

COURSE OVERVIEW

Microprocessor-Based relays are now an integral part of many power distribution systems. This hands-on course is designed for test technicians and other persons involved in setting, testing, and diagnosing microprocessor-based relays that protect feeder and bus systems. 
Enroll Now
NUMBER
553
DURATION
4.5-Day
SCHEDULE
8 am-4:30 pm
(final day ends at noon)
INVOLVEMENT
Hands-on
 
CREDITS
3.6 CEUs
TUITION
$2,135

WHO SHOULD ATTEND

This hands-on course is designed for test technicians and other persons involved in setting, testing, and diagnosing microprocessor-based relays that protect feeder and bus systems. 

LEARNING OBJECTIVES

To receive 3.2 CEUs, participants must attend 4.5 days of class (32 contact hours) and attain a minimum average grade of 80% (overall grade will consist of 50% lab practice and 50% final exam). Upon completion of this course and lab practice, the participant will demonstrate that he/she is able to: 

• Outline how the relay is applied in the power system and identify critical components. 

• Interpret external wiring connections and internal logic functions. 

• Follow NETA standards when performing tasks with the microprocessor. 

• Establish communication with the relay. 

• Verify proper operation of relay indicators and output operation. 

• Connect relay test set and perform metering check and field tests. 

• Perform the following relay element tests and interpret the results: 

          - Phase Time Overcurrent 

          - Phase Instantaneous Overcurrent 

          - Ground Time Overcurrent 

          - Ground Instantaneous Overcurrent 

          - Neutral Time Overcurrent 

          - Neutral Instantaneous Overcurrent 

          - Negative Sequence Time Overcurrent 

          - Negative Sequence Instantaneous Overcurrent 

          - Sensitive Ground Time Overcurrent 

          - Sensitive Ground Instantaneous Overcurrent 

          - Bus Undervoltage 

          - Overvoltage 

          - Line Undervoltage 

          - Underfrequency 

          - Synchrocheck

Note: Relays used in lab exercises will be SEL-751A, GE-SR750, and ABB REF615.

PREREQUISITES

Student must bring a laptop and have full administration rights to install software, to complete the class labs. Laptop must have Windows 7 or greater OS. 

Upon enrollment confirmation, an email containing instructions to install required software will be sent to the participant prior to attending the course. Please make sure you install the required software before attending the class.

REQUIREMENTS

AVO Training Institute is committed to the personal safety of each participant and require long pants and ANSI rated “safety-toe” work shoes for lab activities. Lecture courses may involve a tour of a work or shop area and for this reason open-toe shoes and shorts are not considered appropriate attire for the classroom.

Ready to improve your skillset?